Smoke and carbon monoxide alarm service in Modesto and the Central Valley

Smoke and CO alarm service for rentals: every alarm and carbon monoxide device tested, maintained, replaced and recorded across apartment complexes, condominium units, hotels and motels, duplexes and single-family rentals in 32 cities, with the listing, the manufacture date and each test result written down unit by unit.

Device round · Sample
Alarms and CO devices, 24 units10yearsbattery life a sealed-battery alarm has to hold
ListingState Fire Marshal
Manufacture dateOn device
CO deviceFuel or garage
New tenancyOperable

Who owes smoke and CO alarm service

Testing and maintaining the alarms is the owner's job in a rental, not the tenant's. Health and Safety Code 13113.7 places responsibility for testing and maintaining alarms on the owner of a rented multifamily complex, and since 1 January 2014 on the owner of a rented single-family dwelling as well. The alarms have to be operable at the time a new tenancy is created, and entry to reach them takes twenty-four hours' written notice.

The device itself has to meet a specification before it counts. Alarms are approved and listed by the State Fire Marshal and installed to the maker's instructions. Section 13114 requires a battery-only alarm to carry a non-replaceable, non-removable battery capable of powering it for at least ten years, and requires alarms to display the date of manufacture, provide a place to write the installation date, and have a hush feature.

Carbon monoxide runs on a separate rule with a separate trigger. Section 17926 has the owner install a device listed by the State Fire Marshal in each existing dwelling unit that has a fossil fuel burning heater or appliance, a fireplace, or an attached garage, with number and placement taken from the building standards for new construction or from the maker's instructions. The deadlines have passed in turn: single-family dwellings by 1 July 2011, all other dwelling units by 1 January 2013, and hotels and motels by 1 January 2017.

Maintaining the carbon monoxide devices is a continuing duty, and the tenant's report starts the correction. Section 17926.1 has the landlord maintain the devices, allows entry to install, repair, test and maintain them, and requires each to be operable when the tenant takes possession. An owner is not in violation over a deficiency that has not been reported, but corrects one that has.

What smoke and carbon monoxide alarm service includes

1
Schedule and notice

The units to be reached are listed with the manager, and occupied ones take written entry notice with the date, the approximate time and the purpose. Vacant units, common corridors and back-of-house areas are taken in the same pass, so a building is covered without a second set of notices going out.

2
Device inventory

Each device is identified by unit and position, with its type, its listing and the manufacture date printed on it written down.

3
Test and clean

Every alarm and carbon monoxide device is tested at the device, cleaned, and refitted to the maker's instructions.

4
Replace and add

Devices that fail, that cannot be tested or whose date has run are replaced with listed devices, and missing positions are made up.

5
Carbon monoxide check

Units with a fuel-burning appliance, a fireplace or an attached garage are confirmed to have a device in place and working.

6
Record per unit

The result, the installation date written on the device and the manufacture date go on the file, unit by unit, into the client area.

The rule

An alarm is a dated object. The listing on it, the manufacture date printed on it and the installation date written on it are what a file can be built from. A test with no device record behind it proves nothing later.

Where alarm work is needed

Apartment complexes

Whole buildings taken floor by floor, with corridors and plant areas covered in the same visit as the units.

Condominium units

Separate interests reached through the owner or the manager, with the association's own areas handled apart from them.

Hotels and motels

Guest rooms worked around occupancy, where the carbon monoxide deadline for this class of building fell later than for housing.

Single-family rentals

Whole houses where an attached garage puts a carbon monoxide device on the list whether or not there is a gas appliance.

Duplexes and small blocks

One- and two-unit dwellings, which the statute names among the buildings it covers.

Units being re-let

Anything about to be occupied again, because the alarms have to be operable as the new tenancy is created.

Questions about smoke and carbon monoxide alarm service

The owner of a rented multifamily complex, and since 1 January 2014 the owner of a rented single-family dwelling. The landlord also maintains the carbon monoxide devices. A tenant reporting a deficiency is what puts the owner on notice to correct it.

Smoke and carbon monoxide alarm service by city

Alarm work is requested through the commercial property maintenance page for your city, which covers the rental stock and portfolios there.

All 32 cities →